Managing High-Energy Pumps

25 Oct,2023

3.png

Jennifer Cardillo discusses ensuring pump reliability in abrasive service

Maintaining and improving the reliability of pumps used to transport abrasive media can represent a considerable challenge, especially in high-energy applications. Optimising performance and minimising downtime are high priorities in the oil and gas industry – goals that can be achieved by planning maintenance and introducing modern materials technology to existing assets.

Refineries and oil & gas installations both on and offshore, use high-energy pumps in numerous applications to deliver products at high flow rates and head. Each application has its own challenges, especially those involving materials that cause erosion, corrosion or abrasion. The pumps responsible for delivering these materials are under constant attack, and their design directly affects their durability and efficiency.

Tackling Challenges

High-energy pumps, by definition, use large electric motors to drive them, and these can contribute a significant proportion of the energy costs for the operation. Improving efficiency by just one percentage point can deliver substantial savings. However, these pale into insignificance compared to the revenue that can be lost if production has to stop due to unplanned pump downtime.

Clearly, pump redundancy is built into the design of these production facilities, allowing assets to be maintained without affecting output. However, the frequency of these maintenance windows needs to be kept to a minimum to optimise running costs.

Adverse operating conditions can lead to excessive wear and erosion, which needs to be remedied frequently, sometimes every few months. Such repetitive repairs can lead operators to review the pump’s design and compare costs of maintenance against a new asset that could offer improved reliability and efficiency.

Assessing Costs

Capital expenditure and downtime associated with the installation of new pump assets that may have differing foundation and piping requirements can stagnate efforts to improve equipment availability. However, there is a middle-ground that should be considered where existing designs are assessed and upgraded to improve durability while also reducing maintenance costs. Better still, this option will be considerably less costly than investing in a new asset, which may not be as appropriately designed.

Case Study Example

A refinery was experiencing accelerated wear on its coke cutting jet pump, which was incurring significant costs with a mean time between failure (MTBF) of six to ten months. The application required a pump that could deliver a high differential head and handle varied fluids that had a significant content of abrasive fines.

Pump specifications were the following: design: 8-stage barrel diffuser (BB5); speed: 4,200rpm; flow: approx. 1,200gpm (273m3/hr); and discharge pressure: >4,000 psig (275 barg).

The pump was operating with decoking water, which is primarily composed of wastewater from other refinery operations. Typically, the water could contain coke fines at 2,500ppm and residual corrosive media such as hydrogen sulphide.

Frequent operation of the pump at low flow rates had resulted in suction/discharge recirculation damage. After about six months of operation, a loss of material from the thrust bearing caused the rotor to shift onto the thrust pads, resulting in high bearing temperatures. Further inspections found:

Impeller inlet vane eroded due to sub-optimal flow conditions

High-velocity abrasion at the diffuser inlet

Corrosion erosion at the wear ring side faces

Severe erosion of the shaft at impeller waterways

Significant loss of material at running surfaces

Clearances were 300% greater than the original design

The options for improving this situation include replacing the pump with a new product that uses higher-grade materials, replace the damaged components like-for-like, or implement some mechanical design changes and repair the damaged parts using a coating material that will improve durability. Of these three, the last is the most cost-effective solution over the mid-to long-term.

Long-term solutions

Root cause analysis is essential if situations like this are going to be improved. Unless there was a defect in the original materials, replacing parts like-for-like will result in the same outcome. By understanding the cause of the problem, it is possible to deliver a long-term solution.

In this case, the impeller clearances were increased by the abrasive nature of the media, which caused the pump body to be worn away. In addition, sharp corners and high angles of incidence of the media flow paths caused the abrasive particles to wear away the base material.

The first improvement came from redesigning the thrust rings to reduce the angles of incidence and to remove any sharp corners. In addition, radii were added to the wearing parts.

However, greater durability can be achieved through the addition of specialist coatings, which can improve performance and reliability, provided they are applied by service centres that have expert knowledge and understanding. For applications designed to improve wear and corrosion resistance, high-velocity oxygen fuel (HVOF) coatings are commonly used.

Perfect Bonding

Different coatings have slightly varied bonding properties with different substrates, so it is essential to understand the conditions required to achieve a perfect bond. A coatings bond is one of the most critical aspects of its success in service. As such, it should be in focus during all processes associated with coating.

In every refurbishment project, establishing the process specifications are essential to the long-term success and durability of the coating. This involves detailing the approved equipment and process parameters as well as the properties required for the coating acceptance, such as its tensile strength, microstructure characteristics, hardness and surface roughness values.

By inspecting the microstructure and mechanical properties of the coating, it is possible to verify that it was applied to required specifications and that it will provide all of the expected benefits in operation.

Precision Coatings

Returning to the example pump, HVOF is a line-of-sight process, and to optimise the application accuracy, the coatings were applied using a robotic arm equipped with automated thermal spray equipment. The external and, as far as possible, the internal surfaces of the impeller were treated with an erosion-resistant pump coating, while the shaft bore had an anti-galling coating applied to it.

To refurbish the pump shaft to its original dimensions, it was rebuilt using the HVOF coating process. The coating was then surface ground to the original dimensions before being reassembled.

The refurbished pump was reinstalled and monitored carefully to determine the increase in MTBF. In fact, the pump continued to run for two full years before it was re-inspected for wear. By reusing the original parts from the pump and enhancing their wear characteristics with upgraded coatings and components better suited to the requirements of the application, the clearances on the high-pressure bushing were only 0.002 inches (0.05 mm) oversize after two years of service.

Within the same timeframe, if the operator had continued using replacement parts, the cartridge would have been changed twice at this point. Instead, the refinery had made a significant saving in maintenance costs, as well as minimising downtime, by opting to upgrade the parts with a more durable coating and improving the mechanical design of some of the parts.

There are many pumping applications in the oil & gas sector involving fluids that contain abrasive media. Unless the pumps are designed and constructed to handle these challenging conditions, the reliability of this equipment can be substantially affected. Changes in process parameters and applications can cause legacy equipment to be adversely affected, and without specialist intervention, or complete replacement, the maintenance costs can increase dramatically.

High-energy pumps represent a considerable investment, and they are expected to deliver efficient and reliable service, even in challenging environments. By working with a partner that has the expertise and facilities of an original equipment manufacturer (OEM), operators can benefit from a vast reserve of knowledge. Experienced assessment coupled with expert design analysis enable improvements in durability and reliability to be applied to high-energy pumps. These cost-effective solutions represent an ideal opportunity to extend service life and minimise operating costs.


Contact Us

Address:Room 1306, Building 7, Xingguang International Financial Center, Development Zone, Liaocheng City
Tel:0635-8263099
        0635-8262099
Email:admin@aglzc.cn

Online Inquiry
Company Name*
Name*
Phone*
E-mail*
Message
Copyright ? 2018 - Shandong Ao Gang Lian Bearing Co., Ltd. Technical Support - Bearing.cn ICP:鲁ICP备19054627号-1
主站蜘蛛池模板: 看图中一肖一特网址| 92电影网高清在线| 新澳门2023最精准的资料免费公开| 澳门摇钱树网站期期准| 澳门今晚必开号码62| 电视剧听说你喜欢我免费播放| 成人情趣用品自动售卖机 | 澳门百分百精准一肖一码 | 2024奥门天天开好彩| 澳门王中王726322com| 2024澳门六开奖资料结果| 澳门2024年全免资料| 澳彩开奖结果开奖记录表2022年 | 新澳门内部资料精准大全网站| 新澳天天彩免费大全| 白小姐三肖三码历史开奖记录| 626969cm澳彩开奖结果最新| 澳门2023年精准资料大全香| 新澳门内部一点红| 今晚澳门必哪肖?| 2022澳门六肖6码资料| 玩具总动员2| 成人用品店里长啥样| 香港比喻什么生肖| 澳门三肖三码资料大全下载| 澳门六会彩最快开奖结果| 暗夜与黎明电视剧2024在线观看 | 澳门今晚开奖结果预测| 澳门彩龙门客栈资料库图看新i澳门开彩 | 新澳2024最新资料| 电视不需要会员的追剧软件有哪些| 八角笼中电影国语高清观看全剧| 免费追剧app软件不用登录| 澳门三肖三码必中一肖| 2023澳门精准正版资料大全免费提供 | 澳彩开奖记录2023年最新走势图 | 青盲全集在线高清免费观看| 新澳好彩免费资料查询2024年生肖表| 澳门金财神152727| 新奇说影院在线看| 澳门精准快全篇资料|